Exit

Mineral Fibers with NBR Rubber Binder

5300 Mineral Fiber/NBR Rubber Binder

COMPRESSED SHEET GASKET MATERIAL

ASTM F104: F713110-A9B4E12K5M5
5300_Gaskets-756827-edited.jpg

APPLICATION:

Durlon® 5300 is a commercial grade compressed non-asbestos sheet gasket material for moderate service conditions. It is suitable for a continuous operating temperature of 450°F (232°C); or a maximum pressure of 1000 psi (69 bar) at ambient temperature. It is suitable for steam, oil, water, mild alkalis and acids, hydrocarbons and solvents.

COMPOSITION:

Durlon® 5300 contains high strength mineral fibers and fillers bonded with nitrile (NBR) synthetic rubber. A release agent on both sides provides good anti-stick properties.

abs product design assessment:

Durlon® 5300 has the ABS Product Design Assessment (PDA) Certificate 14-HS1146798-PDA for intended service in marine and offshore applications. It is a sealing gasket for steam, oil, water, mild alkalis and acids, hydrocarbons and solvents.

typical properties:

Color: Rust
Fiber: Mineral
Binder: Nitrile (NBR)
Fluid Services: Marine and Offshore Applications in Steam, Oil, Water, Mild Alkalis and Acids, Hydrocarbons and Solvents
Density: 1.6 g/cm3 (100 lbs./ft3
Tensile Strength, ASTM F152: 1,500 psi (10.34 MPa)
Compressibility, ASTM F36: 7 to 17%
Recovery ASTM F36: 40%
Temperature
   Continuous, max

450°F (232°C)
Pressure, max: 1,000 psig (70 bar)
Fluid Resistance - ASTM F146
   IRM 903 oil, 5 h/300°F (149°C)
     Thickness Increase:
     Weight Increase:
   ASTM Fuel B 5 h/70°F (21°C)
     Thickness Increase:
     Weight Increase:


5% Maximum
15% Maximum

5% Maximum
15% Maximum
Nitrogen Permeability ASTM F2378: 0.1 cc/min
Creep Relaxation ASTM F38:  25% Maximum
Flexibility, ASTM F147: 10x
ASTM F104 Line Call-Out: F713110-A9B4E12K5M5
Note: ASTM properties based on 1/16" sheet thickness. This is a general guide only and should not be the sole means of accepting or rejecting this material. The data listed here falls within the normal range of product properties but should not be used to establish specification limits nor used alone as the basis of design.
 

M&Y AND PROPOSED ASTM GASKET CONSTANTS:

THICKNESS 1/16" 1/8"
M
Y psi (MPa)

1.5
1855 (12.8)

2.5
2619 (18.1)

Gasket Constants
Gb psi (MPa)
a
Gs psi (MPa)


474 (3.3)
0.256
48 (0.3)


902 (6.2)
0.253
4 (0.03)
*Gasket Constants based on proposed ASTM Draft 10.1

 

available sheet sizes:

Nominal
Thickness
Sheet Sizes
inches mm
Order Code Sheets
Per Roll
Approx.
Wt/Sheet
lbs (kg)
1/64" 0.5mm 60 x 63
60 x 126
1524 x 1600
1524 x 3200
CS05-060-063
CS05-060-126
20
10
4 (1.81)
8 (3.63)
1/32" 0.8mm 60 x 63
60 x 126
60 x 126
1524 x 1600
1016 x 3200
1524 x 3200
CS08-060-063
CS08-040-126
CS08-060-126
20
10
10
7 (3.18)
9 (4.08)
14 (6.35)
1.0mm 60 x 63
40 x 126 
60 x 126
120 x 126
1524 x 1600
1016 x 3200
1524 x 3200 3048 x 3200 
CS10-060-063
CS10-040-126 CS10-060-126
CS10-120-126
20
10
10
5
9 (4.08)
12 (5.44)
19 (8.62)
29 (13.15)
1/16" 1.5mm 60 x 63
40 x 126 
60 x 126
120 x 126
1524 x 1600
1016 x 3200
1524 x 3200 3048 x 3200 
CS15-060-063
CS15-040-126 CS15-060-126
CS15-120-126
10
5
5
2
15 (6.80)
19 (8.62)
29 (13.15)
58 (26.31)
2.0mm 60 x 63
40 x 126 
60 x 126
120 x 126
1524 x 1600
1016 x 3200
1524 x 3200 3048 x 3200 
CS20-060-063
CS20-040-126 CS20-060-126
CS20-120-126
10
5
5
2
18 (8.16)
24 (10.89)
38 (17.24)
74 (33.57)
1/8" 3.0mm 60 x 63
40 x 126 
60 x 126
120 x 126
1524 x 1600
1016 x 3200
1524 x 3200 3048 x 3200
CS30-060-063
CS30-040-126 CS30-060-126
CS30-120-126
8
4
4
1
28 (12.70)
37 (16.78)
55 (24.95)
110 (49.90)

Standard Testing:

Tests are standard ASTM procedures. Specific information on any test results and the procedure used is available upon request.

Testing vs Operating Conditions:

All test methods provide a standardized procedure to measure specific effects under controlled conditions. The results of any test are not intended to have any direct correlation with service conditions.

_____________________________________________________________________________________________________

Warning: Durlon® Durlon gasket materials should never be recommended when both the temperature and the pressure are at the maximums listed. Properties and applications shown are typical. No application should be undertaken by anyone without independent study and evaluation for suitability. Never use more than one gasket in one flange joint, and never reuse a gasket. Improper use or gasket selection could cause property damage and/or serious personal injury. The data reported is a compilation of field testing, field service reports and/or in-house testing. While the utmost care has gone into publishing the information contained herein, we assume no responsibility for errors. The information and specifications contained in this website are subject to change without notice. This revision cancels and obsoletes all previous editions.
* For applications above Class 300, consult your representative.